ScatterBridge and FlowCytes are synthetic reference particles for forward and side scatter, so instruments can be set to a common standard and tracked over time.

Instrument standardization sets flow cytometers to a common performance baseline so data is comparable across machines, sites and time. ScatterBridge and FlowCytes provide stable, cell-like scatter populations for forward and side scatter setup, giving a consistent target for calibration and ongoing performance tracking without biohazardous material.
Related: scatter controls.
Showing 3 products
Slingshot Bio Reagent
FlowCytes® WBC (Unfixed) are a synthetic, polymer-based cell mimic that are finely tuned to match the physical and optical properties of viable leukocytes, enabling reproducible instrument scatter settings that will match real cellular samples. FlowCytes® have a multi-year shelf life, room temperature storage, low lot-to-lot variability, easy-to-use dropper bottle application, allowing for a convenient alternative to the hassle of biological scatter controls. As synthetic, non-biohazardous materials, they require no special handling or disposal. Resources: Technical Data Sheet Safety Data Sheet Certificate of Analysis
Slingshot Bio Reagent
FlowCytes® WBC (Fixed) are a synthetic, polymer-based cell mimic that are finely tuned to match the physical and optical properties of real, fixed leukocytes, enabling reproducible instrument scatter settings that will match real cellular samples. FlowCytes® have a multi-year shelf life, room temperature storage, low lot-to-lot variability, easy-to-use dropper bottle application, allowing for a convenient alternative to the hassle of biological scatter controls. As synthetic, non-biohazardous materials, they require no special handling or disposal. Resources: Technical Data Sheet Safety Data Sheet Certificate of Analysis Shipping Policy

Slingshot Bio Reagent
ScatterBridge® Scatter Controls are a precision engineered synthetic hydrogel reference control designed to standardize forward and side scatter across flow cytometry instruments. Each vial contains nine distinct hydrogel populations that form a 3×3 grid when plotted on FSC and SSC, spanning scatter coordinates representative of biologically relevant samples. This structure supports consistent calibration, linearity checks and long‑term performance tracking across instruments and sites.ScatterBridge can be used to align scatter settings between instruments, optimize FSC and SSC detection and recalibrate scatter following major instrument service. As synthetic, non-biohazardous materials, they require no special handling or disposal. Product Features Nine distinct hydrogel populations that form a 3x3 grid when plotted on FSC vs SSC. The scatter coordinates of the nine populations span a range of biologically relevant samples. Resources: Technical Data Sheet Safety Data Sheet
Reference particles used to set a cytometer to a defined performance level and keep it there over time. Scatter standardization controls give forward and side scatter a consistent target, so data stays comparable across instruments and runs.
Calibration sets an instrument's measurements against a known reference. Standardization uses that to bring multiple instruments, or one instrument over time, to a common baseline, so results can be compared across sites and dates.
Talk to our team about setting a common scatter baseline across your fleet with ScatterBridge and FlowCytes.