• Products
    • ViaComp®
    • Ultra™ – Amine
    • Flex
    • SpectraComp®
    • Flex
    • Flex XT
    • Flex Multipeak
    • XT
    • eGFP
    • FluoroCytes
    • SYFP2
    • eGFP
    • tdTomato
    • PhenoCytes™
    • T Cell Activation/Exhaustion Mimic™
    • T Cell Memory
    • TBNK Mimic™
    • CD34+ Stem Cell Mimic™
    • CD4(+), CD4(−) Control
    • StimCytes™
    • BCMA
    • CD19
    • CD20
    • FlowCytes®
    • WBC (Fixed)
    • WBC (Unfixed)
    • NanoCytes™
    • ScatterBridge®
    • QuantCytes™
    • CD19
    • TruCytes™
    • Custom TruCytes™ mimics
    • Browse all products
  • Industries
    • Biopharma
    • Academia and Core Labs
    • Instrument & OEM
    • CROs
  • Resources
    • Scientific Publications
    • Published Articles
    • Application Notes
    • Posters
    • Technical Data Sheets
    • ISO 9001 Certificate
    • Panel Builder
    • Case Studies
    • Blog
    • Webinars
    • Videos
    • How Mimics Work
    • Spectra Viewer
    • All Resources
  • Research
  • Offers
    • New Lab Program
    • Referral Program
  • Company
    • About
    • News
    • Events
    • Leadership
    • Worldwide Distributors
    • Careers
    • Contact
  • Contact Us
  • Shop Now
NEWS: Dr. Nimisha Srivastava Appointed Chief Executive Officer to Lead the Company into Its Next Chapter
Slingshot Logo 2026 TM.svg
Slingshot
  • Research
  • Contact Us
Shop Now

Nature varies. Plastic pretends. We don't. Slingshot Bio. Certainty.

Plastic isn’t biology, donors aren’t reproducible, and animals aren’t human—so stop compromising. Bring high-precision cell mimics into your flow cytometry workflow to achieve consistent, reliable results at every step.

GET IN TOUCH
Slingshot Logo 2026 TM.svg

The New Gold Standard of Flow Cytometry Controls.

Popular Products

  • SpectraComp®
  • ScatterBridge®
  • ViaComp®
  • FlowCytes® Unmixed
  • TBNK™ Mimic

Products by Brand

  • StimCytes™
  • SpectraComp®
  • ViaComp®
  • QuantCytes™
  • ScatterBridge®
  • FlowCytes®
  • PhenoCytes™

Products by Application

  • Viability Controls
  • Spectral Unmixing & Compensation
  • Immunophenotyping Controls
  • Functional CAR‑T Benchmarking
  • Instrument Standardization & Harmonization
  • Quantitative Antigen Density

Technology

  • Three layers. One particle

Learning Resources

  • Blog
  • Case Studies
  • Webinars
  • Videos
  • Events
  • Press Releases

Technical Resources

  • Posters
  • Certificate of Analysis
  • Technical Data Sheets
  • Application Notes
  • Published Articles
  • ISO 9001 Certificate

Company

  • About
  • Leadership
  • News
  • Worldwide Distributors
  • Careers
  • Contact

© 2026 SlingshotBio. All rights reserved.

  • Terms & Conditions
  • Privacy Policy
  • Cookie Policy
  • Cookie Settings
  • Opt-Out
  • Shipping & Return Policy
  • XFollow us on Twitter
  • LinkedInFollow us on LinkedIn
  • InstagramFollow us on Instagram
  • YoutubeSubscribe to our YouTube channel
  1. PhenoCytes™
  2. T Cell Activation/Exhaustion Mimic™

T Cell Activation/Exhaustion Mimic™

T Cell Activation/Exhaustion Mimic™ (SSB-33-A) consists of lymphocyte-like cell mimics that represent different stages of the activation and exhaustion spectrum in CD8+ T cells. In addition, this product includes a synthetic “dead” population capable of binding to either amine-reactive or DNA-intercalating viability dyes. Non-dead populations can be gated with CD45, CD3, and CD8, and can be further gated for CD69, CD25, PD-1, LAG3, TIM3, TIGIT and CTLA4 to serve as positive reference controls for activation and exhaustion markers.

Robust detection of transient activation markers reduces the need for in vitro activation controls. Reliable presence of exhaustion markers rarely found in healthy donor PBMC enables confidence in panel and template development. These synthetic mimics are intended for use as stable, reproducible controls to provide a baseline comparison for longitudinal studies.

SpecificationValue
FormatDefined populations with lymphocyte scatter characteristics
Available Sizes1 test (SSB-33-A) 10 pack (SSB-33-A-10)
Cell Populations1. CD8+ Resting T cells (CD45+, CD3+, CD8+), 2. Early Activated (CD45+CD3+CD8+CD25+CD69+PD-1-), 3. Late Activated (CD45+CD3+CD8+CD25+CD69-PD-1+), 4. Exhausted (CD45+CD3+CD8+CD25-CD69-PD-1+) Exhausted PD-1+ cells can be further assessed for the individual presence of TIM-3, LAG-3, CTLA-4, and TIGIT
BiomarkersCD45, CD3, and CD8, and can be further gated for CD69, CD25, PD-1, LAG3, TIM3, TIGIT and CTLA4
Scatter CharacteristicsEngineered FSC and SSC profiles closely resembling human lymphocyte populations
ApplicationImmunophenotyping QC, T cell activation and/or exhaustion panel verification, antibody performance assessment, instrument standardization, multi-site harmonization, and flow cytometry training
Instrument CompatibilityCompatible across diverse cytometry platforms; supports multi-site standardization
Handling & SafetyNo biohazardous material; no special handling or disposal required
Storage Temp-20°C
Shipping TempNo Ice
Shelf Life24 months
Guaranteed Expiration Date>6 months at shipping
Posters3
Poster

Development of non-biohazardous p24 antigen expressing cell mimics as a reference control alternative to HIV+ donor sample

View
Poster

Cell Mimics as Robust Positive Controls for Immunodeficiency Analyses

View
Poster

Hydrogels Mimicking T, B and NK Cells for Quality Assurance in Cell Therapy Development

View
Application Notes1
Application Note

TBNK Mimic as a Reliable Alternative to PBMC Controls for Consistent Immunophenotyping in Flow Cytometry

View
Published Articles2
Published Article

Evaluation of Cell Mimics as Potential Quality Controls for Human Leukocyte Immunophenotyping

View
Published Article

Synthetic abnormal mast cell particles successfully mimic neoplastic mast cells by flow cytometry

View
Blog Posts1
Blog Post

Stabilizing the Activation-Exhaustion Continuum

September 29, 2026

Read

No frequently asked questions for this product yet.

No reviews for this product yet — be the first to share how it performs in your lab.

T Cell Activation/Exhaustion Mimic™

Packs
Quantity
1
Price$250.00

Product documentation

Product BriefTechnical Data SheetSafety Data SheetCertificate of Analysis (Lot 103150)